5. OPERATION PROCEDURE
5.1 Parameter and Set Values
The set values and setting ranges by parameter at the time of factory shipment are listed in Table
5.1.1 below.
Table 5.1.1 Parameters and Set Values (No.1)
Measurement Condition Parameter
Unit
Ex-factory Set Value
Setting Range
Density multiplier
(C)
―
1.000 (Standard value)
0.00
〜
9.99
Upper density
measurement range (UR)
%
TS
Value specified in your order
1.0
〜
99.9
Lower density
measurement range (LR)
%
TS
Value specified in your order
0.0
〜
99.5
Density line slope (a)
%TS per degree
Value in Table 5.1.2 for each
aperture
- 0.2000
〜
0.2000
Density intercept (b)
%
TS
0.00 (Standard value)
- 99.99
〜
99.99
Density test output
during setting mode (ot)
%
TS
50% density of FS (Provisional
value)
0.0
〜
99.9
Delayed time
in external synchronized
operation
(dt)
Minute
0.5 (Provisional value)
0.1
〜
99.9
Zero-point phase
θ
1
(zp)
Degree
Value at the time
of factory adjustment
0.00
〜
359.99
Zero-point fluid temperature T0 (zT)
℃
Value at the time
of factory adjustment
0.00
〜
100.00
RF correction factor
(cG)
−
Value at the time
of factory adjustment
-9.99
〜
9.99
Zero-point RF data (zG)
−
Value at the time
of factory adjustment
0.00
〜
100.00
Moving average times
(ma)
Time
1 (Without moving averaging)
1
〜
99
Permissible width of
change-rate limit
(dx)
%TS
0.00 (NONE)
0.00
〜
9.99
Limit times of
change-rate limit (HL)
−
0 (Without change-rate limit
)
0
〜
99
Upper angle of angle
rotation correction (UH)
Degree
260
240
〜
360
Upper angle of angle
rotation correction (SH)
Degree
100
0
〜
120
Linearizer density A (LA)
%TS
0.60 (Provisional value)
0.00
〜
99.99
Linearizer density B (LB)
%TS
1.00 (Provisional value)
0.00
〜
99.99
Linearizer inclination (K1)
−
1.00 (Without linearization)
0.00
〜
9.99
Linearizer inclination (K2)
−
1.00 (Without linearization)
0.00
〜
9.99
Linearizer inclination (K3)
−
1.00 (Without linearization)
0.00
〜
9.99
Electric conductivity correction factor
γ
(r)
Degree
(per mS/cm)
00 (Without electric conductivity
correction)
0.00
〜
99.99
Zero-point electric conductivity
Eo (zE)
mS / cm
0.00
0.00
〜
10.00
Measured object electric conductivity (EC)
mS / cm
0.00
0.00
〜
10.00
Содержание Density (Consistency) Meter LQ500
Страница 1: ...6 F 8 A 0 5 2 1 OPERATION MANUAL DENSITY METER TYPE LQ500 ...
Страница 2: ......
Страница 51: ... 49 6 F 8 A 0 5 2 1 ...
Страница 61: ... 59 6 F 8 A 0 5 2 1 ...
Страница 93: ... 91 6 F 8 A 0 5 2 1 mode from the setting mode to resume the normal measurement ...
Страница 113: ......