218
ACE-tronics G9 ASD Installation and Operation Manual
Input Function Target 2
Program
My Function
My Function Unit 4
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 2
terminal.
This setting assigns the function of the programmable Input Function Target 2
terminal to any one of the user-selectable functions listed in
Table 9 on pg. 241
,
Table 10 on pg. 242
, or
Table 12 on pg. 245
.
See
F977
for additional information on this parameter.
Direct Access Number — F937
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Input Function Command 2
Program
My Function
My Function Unit 4
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/Reset function.
Table 13 on pg. 247
lists the available selections. Their use and selection
requirements are described in an example at
F977
.
Direct Access Number — F938
Parameter Type — Selection List
Factory Default — 0 (NOP)
Input Function Target 3
Program
My Function
My Function Unit 4
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 3
terminal.
This setting assigns the function of the programmable Input Function Target 3
terminal to any one of the user-selectable functions listed in
Table 9 on pg. 241
,
Table 10 on pg. 242
, or
Table 12 on pg. 245
.
See
F977
for additional information on this parameter.
Direct Access Number — F939
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Output Function Assigned
Program
My Function
My Function Unit 4
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the Output Function Assigned terminal.
This setting assigns the function of the programmable Output Function
Assigned data location to one of the functions listed in the Input Setting field
of
Table 10 on pg. 242
.
Settings:
0 – 3099
See
F977
for additional information on this parameter.
Direct Access Number — F940
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Input Function Target 1
Program
My Function
My Function Unit 5
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 1
terminal.
This setting assigns the function of the programmable Input Function Target 1
terminal to any one of the user-selectable functions listed in
Table 9 on pg. 241
,
Table 10 on pg. 242
, or
Table 12 on pg. 245
.
See
F977
for additional information on this parameter.
Direct Access Number — F941
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
F937
F941