206
ACE-tronics G9 ASD Installation and Operation Manual
Communications Option Speed Switch Monitor DeviceNet/
CC-Link
Program
Communications
Communication
This parameter is used in the setup of the communications network by reading
the hardware-specific settings of the option card being used with the ASD.
If using the DEV002Z Devicenet card, this parameter reads the hardware
switch SW300 setting of the Devicenet card. SW300 sets the baud rate and the
MAC address of the option card that is connected to a node of the
communications system.
Direct Access Number — F854
Parameter Type — Hardware Selectable
Factory Default — Option-Specific
Changeable During Run — No
Minimum — 0
Maximum — 255
Timed-Run Run-Time
Program
Crane/Hoist
Timed-Run
This parameter sets the amount of time that the ASD outputs the commanded
speed (from RR, Communications, etc.). The Timed Run is activated by
assigning a discrete terminal to Timed Run and momentarily activating the
assigned terminal.
If activated longer than this time setting, the Timed Run will repeat at the rate
setting of
F862
.
Direct Access Number — F861
Parameter Type — Numerical
Factory Default — 1.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 5.0
Units — Seconds
Timed-Run Repeat Delay
Program
Crane/Hoist
Timed-Run
If the Timed Run input terminal remains activated past the Timed Run
duration setting (
F861
), this parameter setting will determine the wait-time
before restarting the Timed Run sequence.
Direct Access Number — F862
Parameter Type — Numerical
Factory Default — 1.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 5.0
Units — Seconds
Super Creep Pulse Count
Program
Crane/Hoist
Super Creep Control
This parameter requires that a discrete input terminal be set to Super Creep for
activation (see
Table 7 on pg. 236
). Any unused discrete input terminal may be
assigned to the Super Creep function.
Activating the Super Creep terminal rotates the motor for the amount of
encoder pulses set at this parameter at the frequency setting of
F865
.
Note:
Available in closed-loop operation only.
Direct Access Number — F863
Parameter Type — Numerical
Factory Default — 1024
Changeable During Run — Yes
Minimum — 0
Maximum — 16383
Units — Pulses
Super Creep Speed Repeat Delay
Program
Crane/Hoist
Super Creep Control
If the Super Creep Pulse Count (
F863
) discrete input terminal remains
activated past the Super Creep Pulse Count setting, this parameter setting will
determine the wait-time before restarting the Super Creep Pulse Count
sequence.
Direct Access Number — F864
Parameter Type — Numerical
Factory Default — 2.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 60.0
Units — Seconds
F854