Page 5-26
Document Ref 942583-001 Rev 8
Installation
Quantium 510 Installation Manual
3)
Apply a sealant compound to the fuel supply riser
and to the inside of the flexible coupling.
4)
Fit the flexible coupling to the fuel supply riser pipe.
Note : Hand tighten only at this point.
5)
Insert the top hat filter (provided in the installation
kit) into the flexible coupling.
6)
Manoeuvre the flexible coupling into the correct
position, ready for securing to the filter box.
7)
Insert the gasket between the filter box and the
flange on the flexible coupling.
8)
Fit the flange to the filter box using the two screws
provided in the installation kit.
Note : Hand tighten only at this point.
9)
Use a large adjustable spanner to tighten and secure the flexible connection to
the fuel supply riser pipe.
10) Using a 15mm spanner or socket, tighten the two screws on the flange.
11) Repeat steps 1 to 10 for each hydraulic position.
TQP-RS PUMPS WITH INTERNAL FILTER
1)
If the riser pipe is not 1.5” diameter male thread
then an adaptor will need to be fitted by the Installer.
2)
Fit the female end of the flexible connection to the
male thread on the fuel supply pipe in the ground
and tighten using a large adjustable spanner.
3)
Where fitted, remove the hygiene cover on the inlet
connection on the pump.
4)
Using a 13mm spanner, fit the two bolts on the
flange to secure the flexible connection to the pump.
5)
Repeat steps 1 to 4 for each hydraulic position.