Document Ref 942583-001 Rev 8
Page 5-23
Quantium 510 Installation Manual
Installation
M12 NUT
Alternative to nut & washer :-
Welded nut on groundframe
with min. 5 captured threads
M12 BOLT high tensile
WASHERS
min thickness = 2mm
min dia = 25mm
Steel groundframe/
sump frame
Underside of
dispenser driptray
TYPICAL FIXING INTO TOKHEIM GROUNDFRAME
TYPICAL FIXING INTO THIRD PARTY GROUNDFRAME / SUMP
FRAME
WASHER
min thickness = 2mm
min dia = 25mm
Underside of
dispenser driptray
M12 ANCHOR BOLT FOR
CONCRETE high tensile
100
Min depth into
concrete = 100mm
Nut insert
Tokheim groundframe
Underside of
dispenser driptray
M10 BOLT high tensile
WASHER
min thickness 2mm
min dia 25mm
5.4.9
FIXING TO GROUND
The following information relates to a typical Tokheim dispenser, unmodified by
the user, with no additional advertisement boards, canopies or items added to the
dispenser. Any such modifications may affect the stability and have warranty/
liability consequences.
IMPORTANT:- Tokheim dispensers must be secured to the ground
using all 4 mounting positions provided in the driptray - refer to the
groundplan drawings in section 3 for mounting hole positions.
FIXING INTO CONCRETE (NO GROUNDFRAME)