Document Ref 942583-001 Rev 8
Page 2-29
Quantium 510 Installation Manual
Site Preparation
VR Connection with Shear Point & Flame Arrester for Ethanol
Kit 1 - Tokheim Part No 943143-001
VR Per Product (Ethanol Split Only)
The diagram below shows the positions of the VR Return Line and the Ethanol
VR Return Line when the option Vapour Per Product (Ethanol Split Only) is
chosen:
VR Riser Pipe
with
male
thread
G1"
904587
900015-022
900758-003
901596
901859
901320-001
900011-004
901772
900416
943050-001
903184
903184
Insulation Sleeve
Gasket
M10 Nut
Shear Valve
U Clamp
U Clamp
Flame Arrester
G1"- G
3
4
" Nipple
(Under Clamp)
Nipple
Flange 1" 78mm
Flange on Dispenser
VR Flexi
M10x45 Bolt
IMPORTANT
Assembly below the shear point
must be secured to the ground
frame (NOT dispenser frame)
Underside of dispenser
70
Driptray
height
86
70
Terminate VR Pipe
70mm below dispenser
NOTE : All threads must be
sealed using Loctite 577
Содержание Quantium 510
Страница 1: ...Document Ref 942583 001 Rev 8 04 2015 Quantium 510 Installation Manual...
Страница 10: ...8 Document Ref 942583 001 Rev 8 Contents Quantium 510 Installation Manual This page is intentionally blank...
Страница 133: ...Document Ref 942583 001 Rev 8 Page 5 47 Quantium 510 Installation Manual Installation This page is intentionally blank...