2.4
Clamping parameters
On CLAMPING screen press F2 CLAMPING PARAMETER
,
or use the directional key in the
main menu to move the cursor to CLAMPING REF.
,
press ENTER if the massage area show
[Lock mode key in password…02]
,
after the correct password is input
,
press ENTER twice to
access to this screen. (Press ENTER the first time is to confirm the password while press
ENTER the second time is to display the screen.)
V1: 0/ 0
0/ 0
V2:
0/ 0
P1: 0/ 0
P2:
100.0mm
100.0mm
210.0mm
0.5mm
ACTION STATUS
M:
03D05M07Y
10h25m10s
20°C
3W
CLAMP DECOMPRESS
RE-CLOSE COUNT
OFF
< 0 > 0
F2
F1
F3
F4
F5
F6
F7
F8
MOLD ADJ.
LOG
SUPPORT
TENANCE
MENU
20
I/O
EJECT ON FLY PT.
< 20.0> 0.0
LUBRICATION T.
< 100 > 10
LUB. COUNT
<200.0>
CLAMP PRESS SLOPE
OFF
OFF
CLAMP SPEED SLOPE
INJ. COMPRESS
OFF
< 45.0>
MOLD COMPRESS PT.
OFF
INTERVAL T. COUNT
OFF
CHARGE ON FLY
CLOSE RELEASE
OFF
OPEN
CLOSE
< 2 >
< 2 > SECTION
SECTION
RAMP
DECOMPRESS PT.
< 50.0>
< 300 > 0 HR
mm
mm
P/V
CHANGE
MOLD
EXTERN
MAIN-
E
H
G
B
A
D
C
F
I
J
K
M
L
N GREASE LUB. T. *1hr
Screen 4-7
A
CLAMP DECOMPRESS
:
After screw charge
,
the mold open to DECOMPRESS PT.
position and stop waiting for the completion of cooling
,
then open again to open end
position.
B
DECOMPRESS PT.
:
Clamp pre opening position for clamp decompression function.
C
INJ. COMPRESS
:
When this function is on
,
mold close will stop at MOLD COMPRESS
PT.
,
then injection starts
,
after injection process is finished
,
mold close to CLOSE END
position. This can achieve single stage injection compression.
D
MOLD COMPRESS PT.
:
Mold close midway stop position for INJ. COMPRESS function.
E
INTERVAL T. COUNT
:
Disable interval timer when set on
,
usually used in mold setup
mode.
F
CHARGE ON FLY
:
Option feature
.
When set on
,
mold can be opened while charge is still
in progress.
G
CLOSE RELEASE
:
When set on
,
performing sensitive mold protection function by
Содержание TMC 1000E
Страница 20: ...Injection Molding Machine Chapter 2 2 4 V3 0 2 Machine dimensions ...
Страница 21: ...Injection Molding Machine Chapter 2 2 5 V3 0 3 Operating position ...
Страница 22: ...Injection Molding Machine Chapter 2 2 6 V3 0 4 Safety devices layouts ...
Страница 23: ...Injection Molding Machine Chapter 2 2 7 V3 0 5 Position of signs and labels ...
Страница 75: ...Injection Molding Machine Chapter 4 V3 0 4 32 starts running to cool down barrel ...
Страница 132: ...Injection Molding Machine Chapter 6 V3 0 6 11 4 3 Lubrication points and timing ...
Страница 136: ...Injection Molding Machine Chapter 6 V3 0 6 15 32 061 120 3141 Nozzle head S45C PCS 1 ...
Страница 148: ...Injection Molding Machine Appendix A A 3 V3 0 1 3 CARRIAGE ADVANCE If CARRIAGE MOVEMENT ON then CARRIAGE ADVANCE ...
Страница 149: ...Injection Molding Machine Appendix A A 4 V3 0 1 4 INJECTION INJECTION ...
Страница 150: ...Injection Molding Machine Appendix A A 5 V3 0 ...
Страница 151: ...Injection Molding Machine Appendix A A 6 V3 0 1 5 CHARGING ...
Страница 152: ...Injection Molding Machine Appendix A A 7 V3 0 If CARRIAGE MOVEMENT ON then CARRIAGE RETRACT ...
Страница 153: ...Injection Molding Machine Appendix A A 8 V3 0 1 6 CLAMP OPENING ...
Страница 159: ...Injection Molding Machine Appendix A A 14 V3 0 1 9 2 GAS VENT SEQUENCE ...
Страница 160: ...Injection Molding Machine Appendix A A 15 V3 0 1 9 3 INJECTION COMPRESSION SEQUENCE ...
Страница 161: ...Injection Molding Machine Appendix A A 16 V3 0 1 9 4 GAS VENT INJECTION COMPRESSION ...
Страница 168: ...Injection Molding Machine Appendix C C 0 V3 0 Appendix C Robot Connection 1 Signal Definition C 1 2 Wiring Example C 2 ...