Injection Molding Machine Chapter 5
V3.0
5-4
item Possible
causes
Solution
1.8
No charge
A Temperature condition not ready
B Charge position
,
pressure
,
speed
,
time are not set properly
C Barrel temperature insufficient
D Charging delay time is set too long
E Pre-suck back function is on.
F Charge back pressure too high
G No material in the barrel.
H Carbonized material in the barrel.
I Resin temperature too high or
gasified.
J Screw check valve worn out
K Directional valve stuck
L
Directional valve signal wire
failure
M Hydraulic motor torque
insufficient
N Quill damaged
A Check temperature setting page
B Adjust parameter setting
C Check temperature control system
D Adjust parameter setting
E Revise function setting
F Lower down back pressure setting
G Check hopper
,
barrel feeding port
H Remove barrel for cleaning
I Clean
barrel
J Replace screw tip assembly.
K Clean and repairV16
,
V16-1
L Repair signal wire 266/0
M Increase pressure or replace hydraulic motor
N Add grease
,
replace bearing
,
key
,
quill.
1.9
No carriage adv. / ret
.
A Position
,
pressure
,
speed are not
set properly
B Directional valve stuck
C
Directional valve signal wire
failure
A Adjust parameter setting
B Clean V21
,
V22
,
manually press spool
C Repair signal wire 271/0
,
272/0
Содержание TMC 1000E
Страница 20: ...Injection Molding Machine Chapter 2 2 4 V3 0 2 Machine dimensions ...
Страница 21: ...Injection Molding Machine Chapter 2 2 5 V3 0 3 Operating position ...
Страница 22: ...Injection Molding Machine Chapter 2 2 6 V3 0 4 Safety devices layouts ...
Страница 23: ...Injection Molding Machine Chapter 2 2 7 V3 0 5 Position of signs and labels ...
Страница 75: ...Injection Molding Machine Chapter 4 V3 0 4 32 starts running to cool down barrel ...
Страница 132: ...Injection Molding Machine Chapter 6 V3 0 6 11 4 3 Lubrication points and timing ...
Страница 136: ...Injection Molding Machine Chapter 6 V3 0 6 15 32 061 120 3141 Nozzle head S45C PCS 1 ...
Страница 148: ...Injection Molding Machine Appendix A A 3 V3 0 1 3 CARRIAGE ADVANCE If CARRIAGE MOVEMENT ON then CARRIAGE ADVANCE ...
Страница 149: ...Injection Molding Machine Appendix A A 4 V3 0 1 4 INJECTION INJECTION ...
Страница 150: ...Injection Molding Machine Appendix A A 5 V3 0 ...
Страница 151: ...Injection Molding Machine Appendix A A 6 V3 0 1 5 CHARGING ...
Страница 152: ...Injection Molding Machine Appendix A A 7 V3 0 If CARRIAGE MOVEMENT ON then CARRIAGE RETRACT ...
Страница 153: ...Injection Molding Machine Appendix A A 8 V3 0 1 6 CLAMP OPENING ...
Страница 159: ...Injection Molding Machine Appendix A A 14 V3 0 1 9 2 GAS VENT SEQUENCE ...
Страница 160: ...Injection Molding Machine Appendix A A 15 V3 0 1 9 3 INJECTION COMPRESSION SEQUENCE ...
Страница 161: ...Injection Molding Machine Appendix A A 16 V3 0 1 9 4 GAS VENT INJECTION COMPRESSION ...
Страница 168: ...Injection Molding Machine Appendix C C 0 V3 0 Appendix C Robot Connection 1 Signal Definition C 1 2 Wiring Example C 2 ...