TMP High Performance Vector Control Inverter User Manual
50
P9.24
T8 running mode
7
:
REV
,
Acc/Dec time 4
0
176
+
P9.25
T9 running mode
0
177
+
P9.26
T10 running mode
0
178
+
P9.27
T11 running mode
0
179
+
P9.28
T12 running mode
0
180
+
P9.29
T13 running mode
0
181
+
P9.30
T14 running mode
0
182
+
P9.31
T15 running mode
0
183
+
P9.32
Record function
0: Disabled
1
:
Record
,
not store after power off
2
:
Record
,
store after power off
0
184
+
PA Group
PID parameters
PA.00
PID
control
characteristic
0: Positive characteristic
1: Negative characteristic
0
185
+
PA.01
Reference selection
0: Panel Digital setting
1: External analog signal AI1
2: External analog signal AI2
3:Communication
4: Panel potentiometer setting (0~5V)
0
186
+
PA.02
Feedback
channel
selection
0: External analog signal AI1
1: External analog signal AI2
0
187
+
PA.03
Digital
setting
of
reference
0.00~10.00V
5.00
188
#
PA.04
Minimum reference
0~100%
0
189
+
PA.05
Maximum reference
0~150%
100
190
+
PA.06
Minimum feedback
0~100%
0
191
+
PA.07
Maximum feedback
0~150%
100
192
+
PA.08
Proportional gain
0.00~10.00
1.00
193
#
PA.09
Integration time
0.01~99.99s
0.5
194
#