TMP High Performance Vector Control Inverter User Manual
107
1: Running frequency
2: Output current
3: Output voltage
4: Bus voltage
5: Overload rate
6: Preset line speed
7: Running line speed
8: Output torque
9: PI reference
10: PI feedback
11: Analog input AI1
12: Analog input AI2
13: I/O status(0~511)
14: External counting value
Inpt/output IO status correspond as blow
:
relay1
Y1
X7
X6
X5
X4
X3
X2
X1
Bit8
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
PH.01
Display parameters at stop
Setting range
:
0
~
8
TMP drive has 9 state parameters in stopping state. User can scroll through
them by pressing ►► key during stop state.
Function code PH.01 defines the default display parameter upon power on,
which includes:
0: Frequency setting
1: Preset line speed
2: DC Bus voltage
3: Analog input AI1
4: Analog input AI2
5: I/O status
6: external counting value