TMP High Performance Vector Control Inverter User Manual
108
7: PI reference
8:PI feedback
PH.02
Line speed factor
Setting range
:
0.1
~
100
When line speed is displayed, line speed = Output frequency × Line speed
factor
PH.03 Reserved
PH.04
IPM heatsink temperature
1
Setting range
:
0
~
100
℃
PH.05
IPM heatsink temperature
2
Setting range
:
0
~
100
℃
Display IPM heatsink temperature.
PH.06
1st fault type
Setting range
:
PH.07
2nd fault type
Setting range
:
PH.08
3rd fault type
Setting range
:
PH.06~PH.08 are used for memorizing the latest three fault types, and can
record the voltage, current, frequency and terminal state at the last fault (in
PH.09~PH.13) for checking.
Please refer to Chapter 7 for fault descriptions.
PH.09
Bus voltage at last fault
(
V
)
Setting range
:
0
~
999
PH.10
Output current at last fault
(A)
Setting range
:
0
~
999.9
PH.11
Frequency setting at last fault
(
Hz
)
Setting range
:
0
~
400.0
PH.12
Running frequency at last fault
(
Hz
)
Setting range
:
0
~
400.0
PH.13
I/O state at last fault
Setting range
:
0
~
511
PH.14
Total operating time
Setting range
:
0
~
9999
PH.15
Software version
Setting range
:
0
~
9.99
PH.16 Keyboard
Software version
Setting range
:
0
~
9.99
PH.12At last time, I/O Status correspond as blow:
relay1
Y1
X7
X6
X5
X4
X3
X2
X1
Bit8
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0