Application and Configuration Examples
8-1
Installation Manual for Models ODM-005, ODM-005i, ODM-010, ODM-010i, ODM-020 and ODM-020i
C
HAPTER
8:
Application and Configuration Examples
This section explains how to install and verify the OMNIDRIVE for various modes of operation. The
procedures verify the installation by:
•
Showing how the power and logic wiring is connected.
•
Selecting the Operation Mode setup for the drive.
•
Tuning the drive for a particular motor type and size.
•
Verifying the basic functionality of the drive and motor combination.
How to modify the units of measurement for OMNI LINK displays is explained on page 8-35.
Analog Control
The OMNIDRIVE can be set up as an analog drive in either the Velocity or Torque mode by making the
hardware connections and performing the software setup and tuning described below. The connection
diagram depicts the minimum hardware necessary. Interfacing the drive to an external controller requires
similar circuitry from the controller to J1. Instructions are provided to configure the drive using a PC with
OMNI LINK software, but the optional TouchPad also may be used.
Hardware Set Up
Make the connections described below and shown in the figure.
1. Connect a ±10VDC power source between J1-22 and J1-23 (ANALOG CMND +/-) to provide
the analog speed or torque command.
2. Connect an RS-232 cable between the serial port on the PC and the J4 connector on the drive. A
simple 3 wire cable is depicted in the figure below.
3. Connect a Motor/Feedback cable from the motor to the J2 connector on the drive.
4. Connect a Power cable from the motor to TB1 (terminals R, S, T and
) on the drive.
5. Connect a jumper wire with a toggle switch between the following pins:
•
J1-20 (ENABLE) and J1-26 (I/O PWR)
•
J1-21 (FAULT RESET) and J1-26 (I/O PWR).
These connections provide manual control for enabling or disabling the drive and resetting faults.
The figure below shows the jumper, including normally open toggle switches.
6. Connect an external 12 to 24 VDC poweer source for powering I/O to J1-5 (I/O PWR)
and J1-6 (I/O COM).
7. Connect the drive to a single phase 100/240 VAC, 50/60 Hz power source.
Connection Diagram
Configuration
Carefully check all connections before entering these parameters.
1. Switch the AC Power to ON and verify: