Power Connections
7-1
Installation Manual for Models ODM-005, ODM-005i, ODM-010, ODM-010i, ODM-020 and ODM-020i
C
HAPTER
7:
Power Connections
DC bus, single phase AC power and motor connections are provided on the Terminal Block (TB-1).
T
ABLE
7.1
TB1 – DC Bus and AC Power Terminal Block Connections
Power Wiring Connection Diagrams for the ODM-005, -005i, -010, -010i, -020 and -020i are
provided on page 5-8. Wiring for the external I/O power is described and depicted in the chapter
“Application and Configuration Examples” on page 8-1
Description
Identifier
Terminal
ODM-005 and -005i
ODM-010 and -010i
ODM-020 and -020i
DC Bus + voltage
DC BUS +
1
DC Bus - voltage
DC BUS -
2
100-240 VAC input power
L1 (Line 1)
3
100-240 VAC input power
L2 (Line 2)/
N (Neutral)
4
Safety (earth) ground
5
R phase power to motor
R
6
S phase power to motor
S
7
T phase power to motor
T
8
Motor case ground
9
Intro
DANGER
DC bus capacitors may retain hazardous voltages for several minutes after
input power has been removed, but will normally discharge in several seconds.
Measure the DC bus voltage to verify it has reached a safe level each time
power is removed before working on the drive; or wait for the time indicated in
the warning on the front of the drive. Failure to observe this precaution could
result in severe bodily injury or loss of life.
Intro
WARNING
Motor power connectors are for assembly purposes only. They should not be
connected or disconnected while the drive is powered.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com