4-6
Unpacking, Inspecting, and Storing
24. Choose
Drive Disable
and verify the motor shaft can be rotated by hand.
25. Choose
Drive Enable
and verify the motor shaft has holding torque. (i.e., The shaft cannot be
moved or moves with resistance.)
26. Open the connection between J1-26 and J1-20 to disable the drive.
27. Choose
Close
from the Control Panel window.
A drive completing these steps is functional. If the OMNIDRIVE did
not
pass the steps above, refer to
“Maintenance and Troubleshooting” on page 11-1.
Storing the Unit
Return the OMNIDRIVE to its shipping carton using the original packing materials to enclose the unit.
Store the drive in a clean, dry place that will
not
exceed the following ranges:
•
Humidity: 5% to 95%, non-condensing
•
Storage temperature: -40
°
to 70
°
Celsius (-40
°
to 158
°
Fahrenheit).
TIP
For information on testing digital and analog signals, refer to , “Testing Analog
Output” on page 11-8 and “Testing Analog Input” on page 11-9
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com