19
TC5-8SDA rev.03
TC5-8SDA
TEMPERATURE CURVE
The user can define a temperature curve to adjust the set point
automatically over a given time period.
A curve is defined using six points. Each point specifies a day number
and a set point for that day. Once the points of the curve are defined,
the curve must be activated. The controller will change the tempera-
ture set point every hour in a linear fashion between consecutive
points of the curve. When the last point of the curve is reached, the
temperature set point for that day is maintained until the curve is
reactivated.
NOTES :
i)
All six points of the curve must be specified. If six points are not
needed, repeat the last temperature value for each unnecessary point.
ii) Certain restrictions apply to reduce the risk of errors:
- The highest possible day number is 99.
- Decreasing day numbers are not allowed.
- Increasing temperatures are not allowed.
- The temperature variation cannot exceed 3°F (1.6°C) per day.
Temperature
Days
T
o
1
T
o
2
T
o
3
T
o
4
T
o
5
T
o
6
d4
d25
d35
d50
d70
d80
○○○○
○○○○○○
○○○○○
○○○○
○○○○○○○
○
○○○○
○
○
○○○○○
○○○○