TECHNICAL SPECIFICATIONS
Supply:
- 115/230 VAC (-18%, +8%),50/ 60 Hz, overload and
overvoltage protection fuse F10-1A fast blow.
- 12 VDC for AC back-up supply; can activate stages 1-8 if
supplied with DC back-up voltage.
Stage 1:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, fuse F1-10A slow blow.
Stage 2:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, fuse F2-10A slow blow.
Stage 3:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, fuse F3-10A slow blow.
Stage 4:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, fuse F4-10A slow blow.
Stage 5:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, fuse F5-10A slow blow.
Stage 6:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, fuse F6-10A slow blow.
Stage 7:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, heating or cooling, fuse F7-10A slow blow.
Stage 8:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 6A
FAN,10A RES, heating or cooling, fuse F8-10A slow blow.
Alarm:
ON-OFF output, 115/230 VAC, 50/60 Hz, 30VDC, 3A ,
fuse F9-3A slow blow.
Probes:
Low voltage ( < 5V), isolated from the supply. Operat-
ing range: -40.0° to 120.0°F (-40.0° to 48.9°C). Accuracy:
1.8
o
F (1
o
C) between 41
o
and 95
o
F (5
o
and 35
o
C).
Enclosure:
ABS, moisture and dust-tight.
The room temperature where the controller is located MUST
ALWAYS REMAIN BETWEEN 32
o
AND 104
o
F (0
o
AND 40
o
C).