The display then shows the Defrost display. The bar indicator
shows approximately the percentage of time remaining to
complete the defrost cycle. The bar indicator in Figure 43
shows that the Zone 1 defrost cycle is approximately 25%
complete.
Figure 43: Bar Indicator
See summary of “Initiating a Manual Defrost Cycle” displays
in Figure 44.
Terminating a Defrost Cycle
The defrost cycle terminates automatically when the coil
temperature is greater than or equal to 58°F (14.5°C) or the
defrost timer expires. Defrost can also be terminated by turning
the unit off and back on.
NOTE: If the Rail Alternate feature is set ENABLED then a
defrost cycle will terminate with temperatures greater than or
equal to 70 F (21 C).