Unit Description
21
CYCLE-SENTRY Start-Stop Controls
The CYCLE-SENTRY Start-Stop fuel saving system provides
optimum operating economy.
When CYCLE-SENTRY Mode is selected the unit will start
and stop automatically to maintain setpoint, keep the engine
warm and the battery charged. When Continuous Mode is
selected, the unit starts automatically and runs continuously to
maintain setpoint and provide constant airflow.
Data Logging
There are two separate data loggers. The data is downloaded
through the Flash Drive Only USB port on the front of the
control box using a flash drive and ThermoServ software.
Flash Drive Only USB Port
: Standard USB drives that have
been programmed with ThermoServ can be used in the Flash
Drive Only USB Port. Use of a USB drive eliminates the need
for an on-site computer and does not require cables.
The Flash Drive Only USB port can be used to:
• Download the CargoWatch and ServiceWatch Data Loggers.
• Flashload the Base Controller and HMI Control Panel.
WARNING: The unit can start at any time without
warning. Press the
O
FF
key on the control panel and
place the microprocessor On/Off switch in the Off
position before inspecting or servicing any part of the
unit.
Содержание Precedent C-600M
Страница 2: ......
Страница 58: ...Operating Instructions 56 Figure 44 Initiating a Manual Defrost Cycle Defrost Key...
Страница 62: ...Operating Instructions 60 Figure 50 Selecting Cycle Sentry or Continuous Mode Cycle Sentry Continuous Key...
Страница 71: ...Operating Instructions 69 Figure 61 Performing a Pretrip Test 2 From Figure 60...
Страница 85: ...Operating Instructions 83 Figure 83 Displaying and Clearing Alarm Codes 1 See Figure 84...
Страница 86: ...Operating Instructions 84 Figure 84 Displaying and Clearing Alarm Codes 2 From Figure 83...
Страница 164: ...162 CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer...
Страница 165: ......