Unit Description
19
Thermo King X430P
Reciprocating Compressor
The C-600M is equipped with a four cylinder 30.0 cu. in. (492
cm3) displacement Thermo King X430P reciprocating
compressor.
Electronic Throttling Valve
The ETV provides enhanced control of the refrigeration system
as follows:
•
Allows the refrigeration system to fully utilize the power
capabilities of the engine under varying conditions
•
Provides an additional measure of protection against high
discharge pressures
•
Protects the engine from high coolant temperature
shutdowns
•
Provides a means of precise temperature control.
Remote Evaporators
A remote evaporator is mounted on the ceiling of each remote
compartment to provide temperature control for Zone 2 and
Zone 3 (if used).
SMART REEFER 4 Multi-Temp
(SR-4 MT) Control System
The SR-4 MT is a microprocessor control system designed for
transport refrigeration. The SR-4 MT integrates the following
functions: changing setpoint and operating mode, viewing
gauge, sensor and hourmeter readings, initiating defrost cycles,
and viewing and clearing alarms.
The microprocessor components are located inside the control
box, which is located inside the lower roadside service door. It
is used to operate the unit. The control panel is mounted on the
face of the control box. It is clearly visible through an opening
in the lower roadside service door.
See “Operating Instructions” in this manual for more
information about the SR-4 MT Controller.
Depending on the air temperature in the trailer, as sensed by
the microprocessor Base Controller, the unit will typically
operate in one of the following modes:
Содержание Precedent C-600M
Страница 2: ......
Страница 58: ...Operating Instructions 56 Figure 44 Initiating a Manual Defrost Cycle Defrost Key...
Страница 62: ...Operating Instructions 60 Figure 50 Selecting Cycle Sentry or Continuous Mode Cycle Sentry Continuous Key...
Страница 71: ...Operating Instructions 69 Figure 61 Performing a Pretrip Test 2 From Figure 60...
Страница 85: ...Operating Instructions 83 Figure 83 Displaying and Clearing Alarm Codes 1 See Figure 84...
Страница 86: ...Operating Instructions 84 Figure 84 Displaying and Clearing Alarm Codes 2 From Figure 83...
Страница 164: ...162 CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer...
Страница 165: ......