Operating Instructions
76
Unit Level Check Alarms
If the alarm is unit specific, the Alarm Icon will appear at the
right side of the display as shown in Figure 71. Both Zone
Specific and Unit Specific Alarms can exist at the same time.
Figure 71: Alarm Icon
Zone Level Check Alarms
If the alarm is zone specific, the Alarm Icon will appear in the
offending zone as shown in Figure 72. An alarm exists in
Zone 2.
Figure 72: Alarm for Zone 2
Unit Level Prevent Alarms
Prevent Alarms are also indicated by a steady alarm icon at the
side of the display. The unit will be temporarily shut down if a
Prevent Alarm is active. The unit will remain shut down for a
timed restart interval or until the fault conditions are corrected
and then restart. If the unit is in a temporary shutdown, Alarm
Code 84 Restart Null will be present along with the associated
Prevent Alarm. In most cases the unit will restart with reduced
performance to determine if continued operation is possible. If
the alarm does not reoccur with reduced performance then the
unit will then return to full performance. If the unit is operating
with reduced performance Alarm Code 85 Forced Unit
Operation may also be present under some conditions. In
general, if the alarm condition re-occurs a defined number of
times then the alarm is set as a Shutdown Alarm and no further
restarts are possible. The TemperatureWatch screen is disabled
if a Unit Level Prevent Alarm is active.
NOTE: If the Restart After Shutdown feature in the Guarded
Access Menu is set for CONTINUOUS, then an unlimited
number of restart attempts are allowed.
Содержание Precedent C-600M
Страница 2: ......
Страница 58: ...Operating Instructions 56 Figure 44 Initiating a Manual Defrost Cycle Defrost Key...
Страница 62: ...Operating Instructions 60 Figure 50 Selecting Cycle Sentry or Continuous Mode Cycle Sentry Continuous Key...
Страница 71: ...Operating Instructions 69 Figure 61 Performing a Pretrip Test 2 From Figure 60...
Страница 85: ...Operating Instructions 83 Figure 83 Displaying and Clearing Alarm Codes 1 See Figure 84...
Страница 86: ...Operating Instructions 84 Figure 84 Displaying and Clearing Alarm Codes 2 From Figure 83...
Страница 164: ...162 CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer...
Страница 165: ......