Loading and Enroute Inspections
117
Post-Loading Inspection
1. Make sure all the doors are closed and locked.
2. Start the unit if it was shut off to load.
3. Make sure the setpoints are at the desired settings.
4. One-half hour after loading, manually initiate a Defrost
cycle. If the evaporator coil sensor temperature is below
45 F (7 C), the unit will Defrost. The microprocessor will
terminate Defrost automatically when the evaporator coil
temperature reaches 58 F (14.5 C) or the unit has been in
the Defrost mode for 30 or 45 minutes (depending on
setting).
Post Trip Checks
1. Wash the unit.
2. Check for leaks.
3. Check for loose or missing hardware.
4. Check for physical damage to the unit.
Inspection Troubleshooting
1. If a temperature reading is not within desired temperature
range, refer to the troubleshooting table on the following
pages. Correct problem as required.
2. Repeat the Enroute Inspection every 30 minutes until the
compartment temperature is within desired temperature
range. Stop the unit if the compartment temperature is not
within desired temperature range on two consecutive 30
minute inspections, especially if the compartment
temperature appears to be moving away from the setpoint.
3. Immediately contact the nearest Thermo King Service
Center or your company office.
4. Take all necessary steps to protect and maintain proper
load temperature.
CAUTION: Stop the unit if the compartment
temperature remains more than the desired
temperature range from the setpoint on two
consecutive 30 minute inspections. Contact the
nearest Thermo King Service Center or your
company office immediately. Take all necessary steps
to protect and maintain proper load temperature.
Содержание Precedent C-600M
Страница 2: ......
Страница 58: ...Operating Instructions 56 Figure 44 Initiating a Manual Defrost Cycle Defrost Key...
Страница 62: ...Operating Instructions 60 Figure 50 Selecting Cycle Sentry or Continuous Mode Cycle Sentry Continuous Key...
Страница 71: ...Operating Instructions 69 Figure 61 Performing a Pretrip Test 2 From Figure 60...
Страница 85: ...Operating Instructions 83 Figure 83 Displaying and Clearing Alarm Codes 1 See Figure 84...
Страница 86: ...Operating Instructions 84 Figure 84 Displaying and Clearing Alarm Codes 2 From Figure 83...
Страница 164: ...162 CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer...
Страница 165: ......