Operating Instructions
57
Selecting Cycle Sentry or Continuous
Mode
When Cycle Sentry mode is selected the unit will start and stop
automatically to maintain setpoint, keep the engine warm and
the battery charged. When Continuous Mode is selected, the
unit starts automatically and runs continuously to maintain
setpoint and provide constant airflow. Cycle Sentry or
Continuous may not be available from the Mode menu if
OptiSet Plus is in use. The Cycle Sentry/Continuous selection
affects all zones.
NOTE: Cycle Sentry or Continuous Mode operation can also
be selected from the Main Menu > Mode Menu.
If allowed by OptiSet Plus, Cycle Sentry or Continuous Mode
is selected by pressing the Cycle Sentry/Continuous Key
(Figure 45). The unit is currently operating in Continuous
Mode as shown by the absence of the Cycle Sentry Icon.
Figure 45: Cycle Sentry/Continuous Key
If the unit is operating in Continuous Mode, pressing the Cycle
Sentry/Continuous Key changes the mode from Continuous
Mode to Cycle Sentry Mode. The display confirms the change,
as shown in Figure 46.
If the unit is operating in Cycle Sentry Mode,
the Cycle Sentry Icon will appear in the display.
• The Cycle Sentry Icon appears in the upper
right corner of the Standard Display
(Figure 48).
• The Cycle Sentry Icon appears in the lower
right of the TemperatureWatch Display
(Figure 49).
• If the Cycle Sentry Icon is not shown, the
unit is operating in Continuous Mode.
Содержание Precedent C-600M
Страница 2: ......
Страница 58: ...Operating Instructions 56 Figure 44 Initiating a Manual Defrost Cycle Defrost Key...
Страница 62: ...Operating Instructions 60 Figure 50 Selecting Cycle Sentry or Continuous Mode Cycle Sentry Continuous Key...
Страница 71: ...Operating Instructions 69 Figure 61 Performing a Pretrip Test 2 From Figure 60...
Страница 85: ...Operating Instructions 83 Figure 83 Displaying and Clearing Alarm Codes 1 See Figure 84...
Страница 86: ...Operating Instructions 84 Figure 84 Displaying and Clearing Alarm Codes 2 From Figure 83...
Страница 164: ...162 CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer...
Страница 165: ......