Figure 22: Zone One
The setpoint display appears as shown in Figure 23.
Figure 23: Setpoint Display
The "-" and "+" soft keys are used to increase or decrease the
setpoint until the desired setpoint is shown. Here the setpoint
has been changed to 0°F using the "+" soft key.
Figure 24: Setpoint Changed
The YES and NO soft keys confirm the setpoint change
(Figure 25). When the desired setpoint has been selected using
the "+" and/or "-" soft keys, press the YES soft key to confirm
and load the new setpoint. If the setpoint is changed using the
"+" or "-" soft keys, the change must be confirmed or rejected
by pressing the YES or NO soft key within 10 seconds of
changing the setpoint. A warning beep will sound after 5
seconds as a reminder. Failure to confirm the new setpoint by
pressing Yes or No within 10 seconds of changing the setpoint