PRePARATION
11
© TESVOLT We reserve the right to make technical changes. Version RD.TI.015.E.ENG_Installation_Manual_TS48V_v.C.01 Last revised 06/2020
CAUTION!
Please also follow the safety information in section “3.3 Transport at the end customer’s site” on page
11 below, especially when loading and unloading.
WARNING! Risk of damage to the unit during transport with installed battery modules.
Transporting the cabinet with battery modules installed causes damage to the unit. The battery mod-
ules and cabinet must always be transported separately from one another. Never move a cabinet once
fitted with modules or, in particular, suspend it using a lifting device.
WARNING! Risk of damage to the battery modules if transported incorrectly.
No more than five battery modules may be stacked on top of each other during transport as they may
incur damage due to their high dead weight.
3.3 TRANSPORT AT THE END CUSTOMER’S SITE
CAUTION! Risk of injury due to improper transport of the battery modules.
Battery modules are heavy (36 kg) and can cause injuries if they topple over or slide around. Ensure that
transport is carried out safely and that only suitable means of transport are used.
CAUTION! Risk of injury due to the battery cabinet toppling over during transport.
The cabinet usually weighs over 100 kg and may topple over if tilted excessively, causing injuries or
material damage.
CAUTION! Risk of injury if safety shoes are not worn when the cabinet is being transported.
If hazards occur, injuries such as crushing injuries can occur due to the heavy self-weight of compo-
nents when the cabinet or battery modules are being transported. For this reason, all individuals
involved must wear safety shoes with protective toe caps.
CAUTION! Risk of injury from sharp edges and metal panels when transporting the cabinet.
When the unpacked cabinet is being transported or installed, there is an increased risk of injury, par-
ticularly due to sharp-edged metal panels. For this reason, all individuals involved must wear safety
gloves.
WARNING! Risk of damage to the unit during transport with installed battery modules.
Transporting the cabinet with battery modules installed causes damage to the unit. The battery mod-
ules and cabinet must always be transported separately from one another. Never move a cabinet once
it is fitted with modules or, in particular, suspend it using a lifting device.
NOTE: Transport by at least two people.
We recommend using a hand truck. Caution: Do not damage the housing and mounting components!
The individual components of the TS 48 V can weigh over 100 kg which makes them unsuitable for
transportation by one person. We recommend at least two people install the system. A dolly or hand
truck is helpful during the installation process.
No more than five battery modules may be stored or
transported one on top of the other.