cONNecTION TO The sMA suNNy IslANd
41
© TESVOLT We reserve the right to make technical changes. Version RD.TI.015.E.ENG_Installation_Manual_TS48V_v.C.01 Last revised 06/2020
Assembly distances for SMA Sunny Islands/Bat fuse and connecting cable lengths
When using the Bat Fuse to Sunny Island (10 m) DC connector kit
17
,
the components must be
arranged in a specific order as this is the only way to maintain the calculated lengths for the connect-
ing cables.
Refer to the table below for the calculated lengths of the connecting cables. The assembly arrange-
ment and the distances between the components are shown in the figure below.
LENGTH
POLE
POINT OF CONNECTION 1
POINT OF CONNECTION 2
200 cm
Positive
Bat Fuse
Master Sunny Island
200 cm
Negative
Bat Fuse
Master Sunny Island
100 cm
Positive
Bat Fuse
Slave 1 Sunny Island
100 cm
Negative
Bat Fuse
Slave 1 Sunny Island
200 cm
Positive
Bat Fuse
Slave 2 Sunny Island
200 cm
Negative
Bat Fuse
Slave 2 Sunny Island
Table 7.1. Lengths of connecting cables when using the Bat Fuse to Sunny Island DC connector kit
30
30
35
All dimensions in cm.
Master
Slave 2
Slave 1
Figure 7.2 Correct distances between the components for fitting the Bat Fuse to the Sunny Island using the DC connector kit