EN
41
E
N
37878
05-2017
4
.
M
ai
n
te
n
an
ce
a
n
d
c
le
an
in
g
4.6
Trouble shooting
Alarm message 14 to 24
ã
Terberg Machines B.V., IJsselstein, The Netherlands
All rights reserved. No part of this book may be reproduced, stored in database or retrieval system, or published, in any form or in any way,
electronically, mechanically, by print, photoprint, microfilm or any other means without prior written permission from the publisher.
14: ERROR REFUSE
SENSOR N10 L/H
L/H refuse (N10) sensor input has detected an
object for longer than 180 seconds.
Check for any debris build up in front of the
sensor.
Check sensor and sensor cable.
15: ERROR REFUSE
SENSOR N10 R/H
R/H refuse (N10) sensor input has detected an
object for longer than 180 seconds.
16: CONTROL STATION
ERROR
Error if one or more of the following buttons are
activated / pressed during start up or after
emergency stop start up. Both button control
stations are checked.
- Up button
- Down button
- Automatic button
- Semi-automatic button
Make sure no button is pressed during start-up or
during the release of the emergency stop buttons.
Check the button stations for water ingress.
Check cables and buttons for damage.
17: ERROR COMB
SENSOR N6 L/H
Message if L/H comb switch (N6) is not switched
on within x milliseconds after start sensor (N1) is
detected.
The bin is presented wrong, please present the bin
in a normal way.
Check the comb sensor.
18: ERROR CYC. START
SENSOR N1 R/H
An object is detected by the R/H start sensor (N1)
much longer than normal.
This can occur if a bin is not taken away from the
bin lift once it has been put down after a normal
emptying cycle.
If this message occurs with no bin or object in front
of the sensor or pedal arm please check the
sensor and cable.
19: ERROR POSITION
SENSOR R/H
This error can be generated by more than one
error and is a global generated position sensor
error for the R/H lifting chair. When the bin is
removed the error will be reset.
Check for mechanical axial and radial play from
the position sensors or adjoined bearings.
Check the position sensor(s).
Check the cables from the position sensors.
Check the analogue values from the position sen-
sors (analogue input 00.2 and 00.3 always
higher than 100, lower than 900).
Recalibrate the position sensors.
20: ERROR TRADE
SENSOR L/H
L/H side trade (4-wheel) recognition sensor (N11)
detects no trade container while the bin lift is in
trade mode and the comb sensor (N6) L/H is
active.
Check the L/H trade sensor.
Check the angle it is looking in (10 degrees
upwards).
Check the sensor cable.
21: ERROR TRADE
SENSOR R/H
R/H side trade (4-wheel) recognition sensor (N11)
detects no trade container while the bin lift is in
trade mode and the comb sensor (N6) R/H is
active.
Check the R/H trade sensor.
Check the angle it is looking in (10 degrees
upwards)
Check the sensor cable.
22: ERROR EMG AND
NEUTRALGEAR ACTIVE
During emergency stop or during the release of
the emergency stop the neutral gear signal from
the refuse body / chassis was not present.
Error will be cleared when neutral gear is switched
on.
The bin lift can optionally be programmed to raise
both lifting chairs to driving height when the neu-
tral gear signal drops. It receives this signal from
the refuse body / truck chassis.
However the bin lift is not allowed to move up or
down spontaneous upon any command directly
out of an emergency or start-up situation.
If this alarm occurs. The chassis / refuse body does
not respect the normal signal sequence. Please
check signals from the refuse body.
23: ERROR COMB
SENSOR N6 R/H
Message if R/H comb switch (N6) is not switched
on within x milliseconds after start sensor (N1) is
detected.
The bin is presented wrong, please present the bin
in a normal way.
Check the comb sensor.
24: MOTOR CONTROLLER
LH
For electric bin lifts with CAN to CAN interface
only. The L/H motor controller has detected one
or more errors.
There is something wrong with the L/H motor
controller or L/H electric motor. Please contact
your local Terberg dealer.