5.9 HEATER CONTACTOR & PUMP MOTOR STARTER
A.
The “standard” mechanical contactor for the heater will cycle proportionally to the amount
of heat input required for the process and may cycle frequently.
B.
This is a “wear” item that must be routinely inspected and replaced when the contacts
begin to indicate wear/pitting.
C.
Failure to maintain the contactor may result in overheating of the components and
catastrophic electrical failure.
D.
The “standard” mechanical pump motor starter must also be routinely inspected and
replaced when the contacts begin to indicate wear/pitting.
Typical electrical panel.
Typical Heater Contactor
Typical Pump Motor Starter
WARNING:
Failure to maintain the contactor may result in overheating of the
components and catastrophic electrical failure.