Temperature Control Units : Veteran with LXG Series Instrument
Page: 90
TEMPTEK, INC.
525 East Stop 18 Road Greenwood, Indiana 46142
317-887-6352 Fax: 317-881-1277
Email: [email protected]
CONDITIONS THAT TRIGGER
AN ALARM OUTPUT ON MOLD
TEMPERATURE CONTROLLERS
CONTROLLER
CONDITION
T G
Incorrect 3Ø power entry
Yes No
Pump overload tripped
Yes Yes
High temperature fault
Yes Yes
Water supply pressure fault Yes Yes
Temperature deviation
Yes Yes
AVT valve malfunction
Yes Yes
Sensor probe malfunction
Yes Yes
BEACON AND AUDIBLE ALARMS ARE SILENCED
DURING AN ALARM CONDITION BY PRESSING
THE START BUTTON ON MICROPROCESSOR
CONTROLLER
8.7 OPTIONAL ALARM OPERATION
A.
The instrument is standard with a 110 volt AC alarm output. The alarm output can be
connected to customer provided alarm annunciation, plant-wide monitoring system or
optional annunciation provided by the factory.
B.
Beacon Alarms used when both visual and audible alarm annunciation is needed. The
beacon is an integral light and buzzer assembly to provide high visibility in a busy, noisy
shop. The beacon will signal until the alarm condition is acknowledged by the operator.
C.
Audible alarms provide a loud signal when an alarm condition is present. The audible
alarm is mounted on the front cover of the unit.
Содержание Veteran VT LXG Series
Страница 2: ......
Страница 6: ...Page 6 THIS PAGE INTENTIONALLY BLANK ...
Страница 20: ...Page 20 THIS PAGE INTENTIONALLY BLANK ...
Страница 42: ...Page 42 THIS PAGE INTENTIONALLY BLANK ...
Страница 48: ...Page 48 THIS PAGE INTENTIONALLY BLANK ...
Страница 68: ...Page 68 THIS PAGE INTENTIONALLY BLANK ...
Страница 95: ...END 2021 TEMPTEK INC RE 20210323 ...
Страница 96: ......