SDI Y-channel CRC Error: Displays the status of the Y channel embedded CRC (Cyclical
Redundancy Check) that was calculated for the video signal. Using a known test signal, the CRC
status can be used to verify integrity through a system. An error means that the Y Channel
embedded CRC value does not match the calculated CRC value, which indicates that a
transmission error has occurred.
•
SMPTE 352M Payload ID Missing: A mandatory SMPTE352M video payload identifier packet is
missing.
•
Video Format Changed: TRS count performed by the instrument does not agree with the line
number embedded in the 292M line.
•
Video Format Mismatch: Detected format of the video-input signal does not match the Input
Format setting (which is set to a specific line rate, rather than being set to Auto) in the SDI Input
submenu of the Configure menu or the setting specified in the SMPTE352 payload (if present).
•
Video Signal Lost: Video input signal has not been detected at the selected input.
Group alarm titles (bold), related alarms, and the related-alarms descriptions
Содержание PRISM MPI
Страница 1: ...PRISM MPI and MPX SDI IP Waveform Monitor User Manual April 2021 D00010020C...
Страница 6: ...6 PRISM MPI MPX User Manual...
Страница 10: ...10 PRISM MPI2 25 MPX2 25 User Manual...
Страница 54: ...Getting Started Activity Center PRISM MPI MPX User Manual 54...
Страница 76: ...Methods of Operation Remote Control through API Commands PRISM MPI MPX User Manual 76...
Страница 138: ...Configure the Instrument Troubleshooting PRISM MPI MPX User Manual 138...
Страница 304: ...PTP Operational Overview Compensating for Causes of Asymmetric Delay PRISM MPI MPX User Manual 304...