25
Installing the Equipment
2.5.3
Connecting to the TSBC3000 Series 1+1 System VoIP Network(s)
Each TSBC3000 series features redundant GigE ports for connection to different VoIP networks. This
provides an access point to manage VoIP traffic. Should one of the IP physical interface go down, the
TSBC3000 series 1+1 session border controller will continue to manage VoIP traffic using the alternate
physical interface.
The IP address of the VoIP ports can be modified using the web portal.
Note:
For full redundancy protection, the TSBC3000 series 1+1 system requires two (2) gigabit
layer 2 Ethernet switches.
Prerequisites
To connect to the VoIP network, you will need:
•
Two gigabit layer 2 Ethernet switches. A second one is required to support redundancy of the VoIP
interface.
•
Four CAT5 Ethernet cables with RJ45 male-male terminations.
Connections
The TSBC3000 series unit and TSBC3000 1 VoIP ports must to be connected on both Ethernet
GigE network links, as shown in
To connect to the VoIP network:
1. Connect the VoIP0 connector from both the TSBC3000 series and TSBC3000 1 units to the
first Ethernet switch.
2. Connect the VoIP1 connector from both the TSBC3000 series and TSBC3000 1 units to the
second Ethernet switch.