Monitoring the SDI Physical Layer
2.
Touch the
Bypass Equalizer
soft key to
toggle the setting on or off:
On
. Bypass the equalizer when the
waveform monitor is connected to a
signal with a short length of cable
to minimize the jitter contributed by
the internal equalizer. This setting is
generally used only for very low-jitter
signals.
Off
. Enables the equalizer, which
enables operation with typical cable
lengths and reduces jitter due to cable
effects. Use this setting for most signals.
CAUTION.
If the equalizer is left in bypass
mode, the waveform monitor will not work
with cables more than a few meters long.
This applies to all SDI displays.
3.
Touch the
Close Settings
soft key.
To Con
fi
gure Physical Layer Alarms
1.
Press the
Main
front-panel button.
2.
Touch the
Con
fi
g
soft key.
3.
Touch the
Alarm Setup
soft key to open
the alarm setup controls.