CV
Default
Value
Value
Range
Description
117 0
0-255 Continuous or PWM signal Output Mapping FL, RL, Aux1÷Aux6
1
Bit0 = 0(0): FL - PWM signal
–
Fade-in/out
= 1(1): FL - Continuous signal
Bit1 = 0(0): RL - PWM signal
–
Fade-in/out
= 1(2): RL - Continuous signal
Bit2 = 0(0): AUX1 - PWM signal
–
Fade-in/out
= 1(4): AUX1 - Continuous signal
Bit3 = 0(0): AUX2 - PWM signal
–
Fade-in/out
= 1(8): AUX2 - Continuous signal
Bit4 = 0(0): AUX3 - PWM signal
–
Fade-in/out
= 1(16): AUX3 - Continuous signal
Bit5 = 0(0): AUX4 - PWM signal
–
Fade-in/out
= 1(32): AUX4 - Continuous signal
Bit6 = 0(0): AUX5 - PWM signal
–
Fade-in/out
= 1(64): AUX5 - Continuous signal
Bit7 = 0(0): AUX6 - PWM signal
–
Fade-in/out
= 1(128): AUX6 -Continuous signal
1
Aux7÷Aux10 configured in CV185