Page 68 of 118
CV
Default
Value
Value
Range
Description
29
14 =
2 +
4 +
8
0-63
Decoder Configuration Data
1
Bit 0 = 0(0): Locomotive Direction normal
= 1(1): Locomotive Direction reversed
Bit 1 = 0(0): FL controlled by bit 4 in Speed and Direction instructions
= 1(2): FL controlled by bit 4 in Function Group One instruction
2
Bit 2 = 0(0): Power Source Conversion NMRA Digital Only (only DCC)
= 1(4): Power Source Conversion Enabled (DC + DCC)
Bit 3 = 0(0): Bi-Directional Communications disabled
= 1(8): Bi-Directional Communications enabled.
Bit 4 = 0(0): Speed table set by CV2, Cv5, and CV6
= 1(16): Speed table set by CV66÷CV95
Bit 5 = 0(0): One byte addressing (short addressing)
= 1(32): Two bytes addressing (extended/long addressing)
Bit 6
–
Not used
Bit 7
–
Not used
1
Decoder Configuration Data 2 in CV122
2