9.5.1.1.
Table of configuration parameters
To correctly display the parameter values, you need to load them from the low kit,
using the “Read from low kit” function.
After any changes to the parameter values, you need to save them in the low kit using
the “Write to low kit” function.
Id
(Par.)
Units
Name
Description
VISIO
Powered
1
decimal
[Rt]
Transmission Ratio
140
2
[Rvel]
Speed ratio
1
3
mA
[Im]
Minimum braking
0
4
W
[Pmc]
Constant maximum power
200
5
in
cents
[Km]
Power factor correction (constant torque)
100
6
0.1N
[Ca]
User friction torque
40
7
°C
[Tea]
Maximum temperature on the coil
125
8
User
rpm
[RPMmin]
Minimum user SPM (start cut braking ramp)
35
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
1
10
User
rpm
[RpmF2]
Rpm filter threshold
75
11
[Rvel]
Speed ratio (decimal part)
60
12
0.1N
[D_Ca]
User delta friction torque
10
13
-
-
Enable flag for registers a
t address ≥ 100
-
Содержание Vario Excite + 500
Страница 1: ...V VA AR RI IO O E X C I T E REV 4 2...
Страница 2: ......
Страница 4: ......
Страница 10: ...VARIO Excite Service maintenance manual rev 4 2 Page vi Page intentionally left blank...
Страница 18: ...VARIO Excite Service maintenance manual rev 4 2 Page 2 6 2 5 2 EUROPEAN AND OVERSEAS PACKING DIMENSIONS...
Страница 58: ...VARIO Excite Service maintenance manual rev 4 2 Page 5 6 Page intentionally left blank...
Страница 170: ...VARIO Excite Service maintenance manual rev 4 2 Page 7 70 Page intentionally left blank...
Страница 206: ...VARIO Excite Service maintenance manual rev 4 2 Page 9 26 Page intentionally left blank...
Страница 208: ...VARIO Excite Service maintenance manual rev 4 2 Page 10 2 Page intentionally left blank...
Страница 219: ......