6-45
6. DIAG. TEST OPERATION
EO18-33006
6.3.23 Threshold Manual Fine Adjustment for the Feed Gap Sensor
6.3 PARAMETER SETTING MODE
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. A changed threshold fine adjustment value is stored in memory by pressing the [PAUSE]
key.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
Press the [PAUSE] key 25 times.
Press the [FEED] key or [RESTART] key to
fine adjust the threshold for the black
mark sensor manually.
Press the [FEED] key and [RESTART] key
at the same time.
Press the [PAUSE] key.
Continued on Section 6.3.24
Kanji Code Selection.
[FEED] key:
Pressing the [FEED] key one
time is a -1.0V change, up to
0.0V.
[RESTART] key: Pressing the [RESTART] key one
time is a +1.0V change, up to
4.0V.
< 1
D I A G N O S T I C V
>
1 . 0 A
T H
E S H O L D
T
R
1 . 4 V
< 2
P A R A M E T E R S E T
>