2-14
EO18-33006
2. MAJOR UNIT REPLACEMENT
NOTE:
The above values of the cutter life are obtained on condition that the periodically maintained
cutter is used with TOSHIBA TEC-approved supplies by the proper method described in the
manuals.
8.
Confirm each part adjustment. Make any necessary adjustments.
9.
Conduct the following tests and make sure that there is no problem.
1)
Print test with TOSHIBA TEC-specified media and ribbon. (Print tone, print head position, etc.)
2)
Paper skew
3)
Print start position adjustment (Horizontal: Media position, Vertical: Sensor adjustment/
Adjustment by issuing commands)
4)
Communication test
5)
Abnorma noise
6)
Confirm that there are not any other errors.
10. Mount the printer cover.
11. Clean the outside of the printer.
12. Fill out a report form. Hand it to the manager and obtain a signature.
2.12 PERIODIC MAINTENANCE PROCEDURE
No.
1
2
3
4
Part Name
Ribbon Motor
Cutter Unit (Option)
Platen
Feed Rooler
Part No.
FMBB0030501
FMBB0030502
GFM-0065001
FMBC0045501
FMBC0044601
Standard Interval of
Replacement
730 Km
1,000,000 cuts
50 Km
50 Km
6.
Confirm that the problem occurs as reported, and then take corrective action.
7.
Replace the following parts periodically, if necessary. The following table shows approximate
product life for each part.