6-19
6. DIAG. TEST OPERATION
EO18-33006
6.3 PARAMETER SETTING MODE
6.3.3
Back Feed Length Fine Adjustment
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
Press the [PAUSE] key 3 times.
Press the [PAUSE] key.
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
Continued on Section 6.3.4
X axis fine adjustment.
Press the [FEED] key
and [RESTART] key
at the same time.
[FEED] key:
Pressing the [FEED] key one
time is a -0.5 mm change, up to
-9.5 mm. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key one
time is a +0.5 mm change, up to
+9.5 mm. (See NOTE 2.)
< 1
D I A G N O S T I C V
>
1 . 0 A
B A
K F E E D A D J . - 3
C
. 0 m m
< 2
P A R A M E T E R S E T
>
NOTES:
1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a
fast forward.
2. Max. fine adjustment
–
9.9 mm = Key fine adjustment value (
–
9.5 mm) + PC fine
adjustment value (
–
9.9 mm)
When the value reaches the maximum, the value remains unchanged even if the
subsequent fine adjustment is performed.
3. A changed back feed value is stored in memory by pressing the [PAUSE] key.