6-71
6. DIAG. TEST OPERATION
EO18-33006
6.6 RAM CLEAR MODE
6.6.2
Parameter Clear
NOTE:
Confirm that “COMPLETE” is displayed, then turn the power off.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key four times.
Press the [PAUSE] key.
Press the [PAUSE] key.
Select type with the [FFED]
key or [RESTART] key.
Press the [FEED] key twice.
(or press the [RESTART] key.)
Press the [PAUSE] key.
Turn off the power (See NOTE 1)
Press the [FEED]
key and
[RESTART] key at
the same time.
QP:
RAM clear for QP type
QQ:
RAM clear for QQ type
JA:
RAM clear for JA type
Select the QP or QQ type.
P A
A M E T E R C L E A R
R
* *
Q P T Y P E * * *
*
< 1
D I A G N O S T I C V
>
1 . 0 A
< 5
R A M C L E A R
>
N O
R A M C L E A R
C O
P L E T E
M
Press the [PAUSE] key.