6-28
6. DIAG. TEST OPERATION
EM18-33011
6.3.9
Ribbon Type Selection
(Revision Date: Jan. 28 '96)
6.3 PARAMETER SETTING MODE
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. Non-transmissive (NON TRANS.) ribbon cannot be used so the ribbon type must be set to
transmissive (TRANS.) ribbon.
3. A changed ribbon type is stored in memory by pressing the [PAUSE] key.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G .
V 1 . O A
>
Press the [FEED] key.
< 2
P A R A M E T E R
S E T
>
Press the [PAUSE] key ten times.
Select either ribbon type with
the [FEED] key or [RESTART]
key. (See NOTE 1and 2.)
Press the [RESTART]
key. (See NOTE 3.)
R I
B O N
T R A N S .
B
Press the [PAUSE] key.
Continued on Section 6.3.10
Ribbon Motor Drive Voltage
Fine Adjustment.
Transmissive ribbon
Transmissive: With ribbon
Non-transmissive: Ribbon end
Non-transmissive ribbon
Transmissive: Ribbon end
Non-transmissive: With ribbon