6-43
6. DIAG. TEST OPERATION
EM18-33011
NOTES: 1. When there is no change to the print condition, select one of the test print options to issue
the test print.
2. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
3. A selected print condition is activated when the [PAUSE] key is pressed.
4. When the feed gap sensor is selected, the gap between labels becomes 3mm long.
5. Non-transmissive (NON TRANS.) ribbon cannot be used so the ribbon type must be set to
transmissive (TRANS.) ribbon or no ribbon.
6. A label size greater than the image buffer length cannot be designated. The image buffer
length differs according to memory size. If designated, the printer prints in the image buffer,
or the printer stops because of an error.
7. Pressing the [FEED] key changes the label length -1 mm, pressing the [RESTART] key
c1 mm.
8. When an error occurs during a test print, the error message is displayed and printing is
stopped. The error is cleared by pressing the [PAUSE] key and the display shows “<3> TEST
PRINT”. Printing is not automatically resumed after the error is cleared.
< 3
T E S T
P R I N T
>
Press the [PAUSE] key.
Press the [PAUSE] key.
P R
N T
C O N D I T I O N
I
< 3
T E S T
P R I N T
>
Select the test print from
those at the right by
pressing the [FEED] key
or [RESTART] key.
Press the [FEED] key
and [RESTART] key at
the same time.
A designated number of
test prints are issued when
pressing the [PAUSE] key.
(See NOTE 8.)
From
B
of the preceding page.
SLANT LINE (1 DOT)
SLANT LINE (3 DOT)
CHARACTERS
BAR CODE
NON-PRINTING
AUTO PRINT (TRANS.) :
Process test print/Transmissive sensor
AUTO PRINT (REFLECT.) :
Process test print/Reflective sensor
From
A
of the
preceding page.
FACTORY TEST PATTERN
(Revision Date: Feb. 07 '97)
6.4 TEST PRINT MODE