6-32
6. DIAG. TEST OPERATION
EM18-33011
6.3.13 Threshold Manual Fine Adjustment for the Feed Gap Sensor
(Revision Date: Dec. 10 '99)
6.3 PARAMETER SETTING MODE
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. A changed threshold fine adjustment value is stored in memory by pressing the [PAUSE]
key.
3. The above operations do not require any more threshold setting.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G .
V 1 . O A
>
Press the [FEED] key.
< 2
P A R A M E T E R
S E T
>
Press the [PAUSE] key fifteen times.
Press the [FEED] key or [RESTART] key to
fine adjust the threshold for the feed
Gap sensor manually.
Press the [FEED] key and [RESTART] key
at the same time.
Press the [PAUSE] key .
Continued on Section 6.3.14
Kanji Code Selection.
T H
E S H O L D
T
1 . 4 V
R
[FEED] key:
Pressing the [FEED] key one
time is a -0.1V change, up to
0.0V.
[RESTART] key: Pressing the [RESTART] key one
time is a +0.1V change, up to
4.0V.