![TEC B-470 SERIES Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/tec/b-470-series/b-470-series_maintenance-manual_828815010.webp)
2-6
2. MAJOR UNIT REPLACEMENT
EM18-33011
(Revision Date: Apr. 05 '94)
2.5 Replacing the Solenoid
2.5 Replacing the Solenoid
NOTE:
The following procedure can be employed without removing the top cover and left side cover.
1) Before removing the ribbon stopper, check its attaching direction for later installation. Remove the
ribbon stopper from the ribbon shaft on which the ribbon is wound.
2) Remove the two SM-4x8B screws, disconnect the connector CN1 on the RSV PC board to detach the
solenoid unit.
Fig. 2-10
3) Remove the two SM-3x5B screws and disconnect the connector CN2 on the RSV PC board to detach
the solenoid.
Fig. 2-11
Connector CN1 (3 pin)
Solenoid Attaching Plate
Screw (SM-4x8B)
Ribbon Stopper
Ribbon Shaft
CN2 (2 pin)
RSV PC Board
Print Block
Connector CN2 (2 pin)
RSV PC Board
Solenoid
Solenoid Attaching Plate
Screw (SM-3x5B)