6-29
6. DIAG. TEST OPERATION
EM18-33011
6.3.10 Ribbon Motor Drive Voltage Fine Adjustment
(Revision Date: Jun. 28 '96)
6.3 PARAMETER SETTING MODE
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. Max. fine adjustment -15 steps = Key fine adjustment value (-15 steps)+PC fine adjustment
value (-15 steps)
When the value reaches the maximum, the value remains unchanged even if the subsequent
fine adjustment is performed.
3. A changed motor voltage value is stored in memory by pressing the [PAUSE] key.
4. One step corresponds to 5% of the standard voltage and up to 75% of the voltage can be
decreased.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G .
V 1 . O A
>
Press the [FEED] key.
< 2
P A R A M E T E R
S E T
>
Press the [PAUSE] key eleven times.
Press the [FEED] or
[RESTART] key to fine
adjust the rewind motor
voltage. (See NOTE 1.)
Press the [FEED] or
[RESTART] key to fine
adjust the feed motor
voltage. (See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
(See NOTE 3.)
R
N
A D J
< F W >
+ 0
B
R
N
A D J
< B K >
+ 0
B
(Ribbon feed motor voltage fine
adjustment)
(Ribbon rewind motor fine
adjustment)
[FEED] key:
Pressing the [FEED] key one
time is a -1 steps change, up to
-15 steps. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key one
time is a +1 steps change, up to
-15 steps. (See NOTE 2.)
[FEED] key:
Pressing the [FEED] key one
time is a -1 steps change, up to
-15 steps. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key one
time is a +1 steps change, up to
-15 steps. (See NOTE 2.)