6-4
6. DIAG. TEST OPERATION
EM18-33011
■
Sample Print
(Revision Date: Dec. 10 '99)
6.2 SELF TEST MODE
[Print Condition]
• Preset count
:
1
• Print speed
:
6"/sec.
• Sensor
:
No sensor
• Printing method :
Thermal transfer
• Supply length
:
50 mm
• Issuing mode
:
Batch printing
(without rewinder)
1) Maintenance Counter
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(27)
(28)
(25)
(26)
(29)
(30)
(31)
(32)
(33)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
TL FEED
1882.3km
FEED
20.5km
15.0km
CUT
148150
HEAD U/D 170
RIBBON
32h
SOLENOID 0h
232C ERR 1
SYS ERR 0
PW FAIL 0
FONT [PC-850] [0]
CODE [ESC LF NUL]
RIBN [TRANS.]
RIBN ADJ. [PC] +0 +0 [KEY]+0 +0
STATUS [OFF]
THRESHOLD R1.0V
THRESHOLD T 1.4V
KANJI [TYPE1]
MOTOR [TYPE2]
EURO CODE B0H
DTR/RTS [DTR]
INPUT PRIME [ON]
[PC]
FEED
+10.0mm
CUT
-5.0mm
BACK
+3.0mm
TONE(T)
+3step
TONE(D)
+5step
[KEY]
FEED
+5.0mm
CUT
-1.5mm
BACK
+0.5mm
TONE(T)
+0step
TONE(D)
+1step
X ADJ.
+35.0mm
NOTES: 1. Item from (2) through (10) are initialized to “0” after RAM clear.
2. If the distance is 8.2 m or less, it is rounded down and no data is added to the memory at
power off.
3. If the count is 31 counts or less, it is rounded down and no data is added to the memory at
power off.
4. If the driving time is 32 sec. or less, it is rounded down and no data is added to the memory
at power off.
5. When a sent command results in an error, the same number as the data capacity of the
command is counted by byte.
#
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Count Condition
Counted when the feed motor drives to feed, print and issue the
media. (Counted also during ribbon save operation and back
feed.) [See NOTE 2.]
Counted while printing. (Feeding and issuing media, and ribbon
saving operation are not counted.) [See NOTE 2.]
Counts every cut. [See NOTE 3.]
Counts every up and down of the print head using the solenoid
for ribbon save operation. (Up+Down=1 count) [See NOTE 3.]
Counts when the ribbon motor drives to feed, print and issue the
media. (The driving time is not counted during ribbon saving
operation, but is during back feed.) [See NOTE 4.]
Counted during ribbon saving operation. [See NOTE 4.]
Counted when a parity, overrun or framing error occurs. [See
NOTE 5.]
Counted when a zero-dividing error occurs or undefined command
is retrieved.
Counts the number of times the power restores while the CPU is
busy after reset.
Item
Total media distance
covered
Media distance covered
Print distance
Cut count
Head up and down count
Ribbon motor driving time
Solenoid driving time
RS-232C hardware error
count
System error count
Momentary power failure
count
Range
0.0 ~ 3200.0
km
0.0 ~ 200.0 km
0.0 ~ 200.0 km
0 ~ 1000000
times
0 ~ 2000000
times
0 ~ 2000 hours
0 ~ 1000 hours
0 ~ 255 times
0 ~ 15 times
0 ~ 15 times
Fig. 6-1