User Manual
Chapter 7 - Parameters Description 83
F.201 Acc time 1
(Acceleration time 1)
F.202 Dec time 1
(Deceleration time 1)
F.203 Acc time 2
(Acceleration time 2)
F.204 Dec time 2
(Deceleration time 2)
F.205 Acc time 3
(Acceleration time 3)
F.206 Dec time 3 / FS
(Deceleration time 3)
F.207 Acc time 4
(Acceleration time 4)
F.208 Dec time 4
(Deceleration time 4)
N
OTE
!
When the JOG function is activated,
Acc time 4 (F.207)
and
Dec time 4 (F.208)
are selected
automatically.
When the "FAST STOP" is activated (through digital input command), the function is executed with the
DEC TIME 3 delay.
The ramp control can be set for a programmable delay for the acceleration and deceleration times of the drive
reference. This delay time will have to be set on the final system (motor and load), being strictly dependant from
the inertia of the load machine.
The time values are expressed in seconds. The ramps time delay are calculated in accordance with the
Max ref freq (F.020).
It is possible to select up to 4 different time, whose value can be set in these parameters.
The selection of these ramps can be performed through a binary setting of 2 digital inputs, programmed as
Ramp sel 1
and
Ramp sel 2
.
It is reported below the basis sequence for the full selection.
Active Ramp time
Ramp sel 1
Ramp sel 2
F.201 (Acc time 1)
F.202 (Dec time 1)
F.203 (Acc time 2)
F.204 (Dec time 2)
F.205 (Acc time 3)
F.206 (Dec time 3)
F.207 (Acc time 4)
F.208 (Dec time 4)
avy4220
0
0
1
0
0
1
1
1
Code
Name
[Code] & Function.
Default
MIN
MAX
Unit
Variation
IPA
F.201
Acc time 1
5
0.1(***) 999.9(***) sec
0.1 (***) 329
F.202
Dec time 1
5
0.1(***)
999.9(***) sec
0.1 (***) 330
F.203
Acc time 2
5
0.1(***)
999.9(***) sec
0.1 (***) 331
F.204
Dec time 2
5
0.1(***)
999.9(***) sec
0.1 (***) 332
F.205
Acc time 3
5
0.1(***)
999.9(***) sec
0.1 (***) 333
F.206
Dec time 3 / FS
5
0.1(***)
999.9(***) sec
0.1 (***) 334
F.207
Acc time 4 / Jog
5
0.1(***)
999.9(***) sec
0.1 (***) 335
F.208
Dec time 4 / Jog
5
0.1(***)
999.9(***) sec
0.1 (***) 336
(***) value depends on the setting of
F.200