122 Chapter 7 - Parameters Description
User Manual
7.9 Menu H - HIDDEN
This menu is not available on the keypad. The setting and the reading of the parameters here contained, can be
performed exclusively via serial line or through SBI card.
Virtual I/O Commands
H.000 Virtual digital command
Setting of the bits for the virtual commands assignment.
A byte is available for the selection of 8 digital commands, whose setting will interact with the decoder mask.
The status of this mask will determine the switch for a virtual command (high status) or terminal command (low
status).
Defining the mask for a virtual command, the function programmed on the digital inputs (
I.000 I.007
), will be
executed by this parameter in accordance with the setting of its bits.
Bit 1 = 1
Virtual command 1 Enabled
Bit 2 = 2
Virtual command 2 Enabled
Bit 3 = 4
Virtual command 3 Enabled
Bit 4 = 8
Virtual command 4 Enabled
Bit 5 = 16
Virtual command 5 Enabled
Bit 6 = 32
Virtual command 6 Enabled
Bit 7 = 64
Virtual command 7 Enabled
Bit 8 = 128
Virtual command 8 Enabled
The setting of the bits at 0, will mean the disabling of the respective function.
For further information about the function programming, see chapter
INTERFACE
section
Enabling Virtual I/O
.
H.010 Virtual digital state
Setting of the bits for the virtual digital output function assignment.
A structure of 4 bits is available for the selection of the 4 digital outputs, whose setting will interact with the
decoder mask. The status of this mask will determine the switch for a virtual digital output function (high
status) or the function of the drive (low status).
Defining the mask as virtual, the digital outputs function will be executed by this parameter, in accordance with
the setting of its bits.
Bit 1 = 1
Virtual function digital output 1 Enabled
Bit 2 = 2
Virtual function digital output 2 Enabled
Bit 3 = 4
Virtual function digital output 3 Enabled
Bit 4 = 8
Virtual function digital output 4 Enabled
The setting of the bits at 0, will mean the disabling of the respective function.
For further information about the function programming, see chapter
INTERFACE
section
Enabling Virtual I/O
.
Code
Name
[Code] & Function.
Default
MIN
MAX
Unit
Variation
IPA
H.000
0
0
255
1000
H.010
0
0
255
1002