User Manual
Chapter 6 - Using the Drives Control Keys 35
Chapter 6 - Using the Drives Control Keys
This chapter tells you how to use the drives front panel control keys to set drive parameters.
6.1 Control keys and LEDs
Though changes to parameter values are immediately effective, they are not automatically saved. A
specific command, the "
C.000 [Save parameters]
command must be used to save changes.
Interpretation of LEDs:
POWER-PRG
(Yellow LED): Lit = inverter powered on. Flashing = parameter change not yet saved.
RUN
(Green LED): Lit = motor running, Run command enabled and active*.
ALARM
(Red LED): Lit = Drive alarm state.
(*)
N
OTE
:
The green LED flashes to indicate the the motor stall prevention function is active.
M
Menu scroll key: Press to scroll from one parameter menu to the next (
d.xxx,
S.xxx, I.xxx, F.xxx, P.xxx, A.xxx and C.xxx
).
E
Enter key:
Press to access a parameter and/or confirm its value.
▲
UP key:
Press to scroll up through a list of parameters and/or to increment
the value displayed. Also increments the motor potentiometer
reference in the "
F.000 - Motorpot ref
" parameter (F: FREQ &
RAMPS menu).
▼
DOWN key:
Press to scroll down through a list of parameters and/or decrement
the value displayed. Also decrements the motor potentiometer
reference in the "
F.000 - Motorpot ref
" parameter (F: FREQ &
RAMPS menu).
▲
+
▼
UP + DOWN keys: Press simultaneously to reset the drive.