User Manual
Chapter 7 - Parameters Description 47
I
PA
C
ODE
N
AME
PARAMETER
PICK LIST
D
ESCRIPTION
[C
ODE
]
F
UNCTION
D
ESCRIPTION
D
E
FAUL
T
M
IN
M
AX
U
NIT
V
ARIA
TION
FREQ & RAMP
F.000
F.001
F.010
F.011
F.012
F.013
F.020
F.021
F.050
F.051
F.060
F.061
F.100
F.101
F.102
F.103
F.104
F.105
F.106
Motorpot ref
Motorpot ref
unit
Acc/Dec time mp
Motorpot offset
Mp output mode
Mp auto save
Max ref freq
Min ref freq
Ref 1 channel
Ref 2 channel
MltFrq channel 1
MltFrq channel 2
Frequency ref 0
Frequency ref 1
Frequency ref 2
Frequency ref 3
Frequency ref 4
Frequency ref 5
Frequency ref 6
Motopot reference (it can
be set using up and down
commands)
Unit of measure reference
Motorpot Accel. and Decel.
ramp time
Motopotentiometer
minimum reference
Unipolar / bipolar
Motorpotentiometer
Motopotenziometer auto
save function
Motor maximum frequency
value (for both the
directions)
Minimum frequency value
Source of the Reference 1
Source of the Reference 2
Source of the Multispeed 1
Source of the Multispeed 2
Digital Reference frequency 0
Digital Reference frequency 1
Digital Reference frequency 2
Digital Reference frequency 3
Digital Reference frequency 4
Digital Reference frequency 5
Digital Reference frequency 6
[0] Unipolar
[1] Bipolar
[0] Disable
[1] Enable
[0] Null
[1] Analog inp 1
[2]
[3] Freq ref x
[4] Multispeed
[5] Motorpotent
[6]
[7]
[8]
[0] Null
[1] Analog inp 1
[2]
[3] Freq ref x
[4] Multispeed
[5] Motorpotent
[6]
[7]
[8]
Motorpotentiometer
unipolar
Motorpotentiometer
bipolar
Motorpot auto save
function disabled
Motorpot auto save
function enabled
Null
Analog input 1
Not used
Frequency reference
F.100 (S.203)
Multi frequncies
Motorpotientometer
reference
Not used
Not used
Not used
Null
Analog input 1
Not used
Frequency reference
F.101
Multispeed
Motorpotientometer
reference
Not used
Not used
Not used
As for F.050, Reference 1
source
As for F.051, Reference 2
source
0
10
0
0
1
(****)
0
3
0
3
3
0
0
0
0
0
0
0
0
0.1
0
0
0
25
0
0
0
0
0
-F.020
-F.020
-F.020
-F.020
-F.020
-F.020
-F.020
F.020
999.9
F.020
1
1
500
F.020
5
8
8
8
F.020
F.020
F.020
F.020
F.020
F.020
F.020
Hz
sec
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz
300
343
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
M
otorpotentiometer
Reference
Limit
0.01
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Reference
Sources
M
ulti
Frequency
Function