14 - Specifications, etc.
14–6
14.6.11 MIDI
14.6.12 Fatal System Errors
NOTE
These messages should not occur. However,
if you do see such a message, please make a
note of the number displayed, and contact
TASCAM Service. Inform them of the error
and, if possible, a brief description of your
system and the events leading up to the error.
No recovery is possible from these errors—
you must turn down the level of the monitoring
system, power down the TM-D4000 and wait
a few seconds before switching it on again.
●
Host TX Command
Buffer Overflow.
Internal error — note that
some of the data being
transmitted to and from the
TM-D4000 will have been
lost of one of these
messages appears. Re-
attempt the data
transmission.
●
Host TX Bulk
Buffer Overflow.
●
Host RX Bulk
command Buffer
Overflow.
●
Host RX command
Buffer Overflow.
✔
MIDI active
sensing has been
discontinued
This appears if Active
Sensing is turned on and
the Active Sensing mes-
sages stop
✔
MIDI System
Reset Received,
Reboot Mixer?
Provides the option to
honor or ignore a received
MIDI Reset message
✔
Please check
MIDI IN Port
The MIDI connection to the
TM-D4000 may not be cor-
rectly made
●
Please Set Comms
Speed to MIDI in
the Automation
Setup screen
first
An attempt is made to use
the MIDI Bulk Dump func-
tion with a speed other
than MIDI selected as the
communications speed
✘
Fatal Error :
XX-YYYYYYYY-ZZ
An unrecoverable error
has occurred. Contact
TASCAM Service.
●
Out of range in
sram.type=
Though these are not fatal
messages (the TM-D4000
will attempt a recovery
from them), internal mem-
ory may not be completely
as it was before the event
occurred. Check the mem-
ory contents before
continuing.
●
Out of range in
current
sram.tyoe =
●
Unexpected
Effector command
0xXXXXXXXX