14 - Specifications, etc.
14–3
14.5
Physical specifications
14.6
Error and warning messages
Not every one of these messages indicates an error.
The purpose of some of these messages is to let you
know that the status of some of the parameters of the
TM-D4000 have changed.
“User” messages, i.e. those which result from an
invalid entry or selection, are marked with a
●
.
“Confirm” messages, where a response may be nec-
essary to confirm an action or setting, are marked by
a
✔
.
“Fatal” messages, where the TM-D4000 may either
be powered down and reset, or where attention by a
qualified service engineer is required, are marked by
a
✘
.
14.6.1 Clock and synchronization
14.6.2 General
Power requirements
120V AC, 60 Hz (U.S.A./Canada)
230V AC, 50 Hz (Europe)
240V AC, 50 Hz (Australia)
Power consumption
60W
Dimensions of main
unit (w x h x d) mm
(in.)
644 x 237 x 703 (25.4 x 9.3 x 27.7)
Weight
26 kg (57.2 lbs)
✔
New clock source
out of range,
Master Clock is
unchanged
The selected clock source
is outside the limits of tol-
erance (44.1 kHz or 48 kZ,
±6%)
✔
Flags NG
A digital audio source has
been selected as a clock
source, but the flags in the
data show that it cannot be
used for this purpose
✔
PLL Unlocked, so
mixer muted.
The clock signal at the
designated connector is
unstable. To avoid dam-
age to the monitoring
equipment, the TM-D4000
mutes itself.
✔
Master Clock has
gone out of
range, Mixer
muted
The clock signal at the
designated connector is
more than 6% out of the
numinal frequency. To
avoid damage to the moni-
toring equipment, the TM-
D4000 mutes itself.
●
Can't select
Cascade clock
from this screen
The Cascade option is
automatically set and can-
not be changed from the
clock screen
●
You can't change
the clock source
when cascade
slave is
selected
A cascade slave cannot
have its clock source
changed.
✔
Please select
INIT clock
to change FS
Only the internal source
can change the sampling
frequency. Select the INT
source to change the sam-
pling frequency
✔
There is no card
in slotx
An attempt has been made
to select an empty slot as
a clock source
✔
The AD/DA board
has no clock
source
An IF-AD4000 interface
card cannot be used as a
clock source
✔
Mixer will mute
while chcking
When checking trhe clock
source, the TM-D4000
mutes
✔
Clock check
results...
The result of a clock check
operation
✔
Copy to all buss
delay
Confirmation that the same
delay is to be applied to all
busses
●
Can't Unlink
Dynamics with
INPUT Channels
linked
If a pair of channels has
been stereo linked, the
dynamics processors can-
not be unlinked.
●
Can't Unlink
Dynamics for ST-
INx
The dynamics processors
cannot be unlinked for the
stereo input channels
●
Can't Unlink
Dynamics for
STEREO OUT
The dynamics processors
cannot be unlinked for the
stereo output
●
Automation Mode
Select
Connfirms that Automa-
tion Mode is entered, to
remind you that the
SEL
keys now work with the
Automation software.
●
Select Stereo
Mode
Reminder that s achange
has been made to a partic-
ular surround mode or to
the stereo mode from a
surround mode
●
Select Surround
Mode 2 + 2
●
Select Surround
Mode 3 + 1
●
Select Surround
Mode 5.1
●
No Category for
AES/EBU
An attempt was made to
change the SCMS setting
on professional format out-
put data
●
New Category:
xxx
Concerned with SCMS
settings
●
New SCMS: xxx
Concerned with SCMS
settings